C800-Specification
| General | ||
| Topology | Line-interactive | |
| Configuration | Tower | |
| Catalog Series | C800 | |
| Color | Black | |
| Rating (VA/Watts) | 800/480 | |
| Diagnostics | Full system self-test at power up | |
| Efficiency | >95% | |
| Dimensions (H x W x D, inches) | 5.6 x 4.0 x 11.0 | |
| Dimensions (H x W x D, mm) | 142 x 101 x 279 | |
| Weight (kg) | 4.9 | |
| Weight (lbs) | 10.8 | |
| Warranty | 3 years includes batteries | |
| Contents (Ships with the following items) |
UPS USB cable User manual AC input power cable |
|
| Electrical Input | ||
| Connection | (1) IEC320-C14, 10A | |
| Input Cord | 6 ft (1.8m) | |
| Input Voltage Range | 162-290 VAC | |
| Nominal Voltage | 220 VAC | |
| Frequency | 50/60 Hz | |
| Electrical Output | ||
| Output Receptacles | (4) IEC320-C13, 10A | |
| Nominal Voltage | 220 VAC | |
| Battery | ||
| Battery Type | Sealed Lead-Acid maintenance-free battery | |
| Start On Battery | Allows start of UPS without utility input | |
| External Battery Capability | Not applicable | |
| Communications | ||
| Communication Ports | USB HID port as standard, 6-ft USB cable included | |
| Power Management Software | Enhance your power protection and safeguard your data when you pair it with the monitoringsoftware | |
| Environmental & Standards | ||
| RoHS Compliance | Yes | |
| Audible Noise | <40 dB | |
| Surge Protection | Yes. RJ11 jacks for modem line | |
| Operating Temperature | 0 to 40°C (32°F to 104°F) | |
| Safety markings | CE | |
| Safety | UL | |
| Storage Temperature | -15°C – 50°C (5°F – 122°F) | |
| Relative Humidity | 0–90% non-condensing | |