GXR-2000S

GXR-2000S

GXR-2000S Specification
General
Model SMAP GXR-2000S UPS
Topology True on-line double conversion
Configuration Rack/Tower
Catalogue Series GXR, 2U Rack/Tower UPS
Rating (VA/Watts) 2000 / 1800
Dimension (W x D x H, mm) 438 x 630 x 88
Dimension (W x D x H, inches) 17.2 x 24.8 x 3.5
Net Weight 26.9 kg
Efficiency 91%
Transfer Time Zero
Waveform Pure sine wave
Electrical Input
Input Phase Single phase with ground (2 wires + ground)
Input Connection (1) IEC60320 C20, 16A IEC320-16A C20
Voltage Range 110 ~ 300 VAC ± 3%
Input Frequency 50/60 Hz ± 3 Hz (auto sensing)
Frequency Range 40 ~ 70 Hz
Input Power Factor > 0.99
Electrical Output
Output Phase Single phase with ground (2 wires + ground)
Output Receptacle (8) IEC60320 C13, 10A IEC320-10A C13
Output Voltage 220 VAC default; configurable to 208/230/240 VAC
Voltage Regulation ± 1%
Synchronized Frequency Range 50/60 Hz ± 3 Hz
Frequency Regulation 50/60 Hz ± 0.1 Hz
Output Power Factor 0.9
Current Crest Ratio 3:1
Harmonic Distortion (THDU) ≤ 2% (linear load)
Battery
Battery Type Valve Regulated Lead-acid Maintenance Free, Gel, Ni-Cd
Hot-swap Battery Yes
Typical Recharge Time 3 hours
Battery Design Life 3 ~ 5 years
Indicators, Communications & Management
Rotatable LCD Panel UPS status, load level, battery level, input/output voltage, discharge remaining time, and fault conditions
Audio and Visible Alarms Battery mode, low battery, overload, fault
Communications USB / RS-232, SNMP RJ-45 network, intelligent slot
EPO Yes
Optional Accessories Dry Contact, BACnet, SNMP network card, Relay card, Modbus card, External battery Pack, Isolation Transformer, ATS16, Maintenance Bypass Switch
Support Software Windows Family, Linux, Unix, MAC, Hyper-V, VMware, etc.
Environmental & Standards
Operating Conditions 0 ~ 95% RH @ 0 ~ 40°C (non-condensing)
Operating Altitude < 2,000 m
Audible Noise < 48 dB at 1 meter
Safety & Standards IEC/EN 62040-1/2/3, CE

Products&Solutions

  • Home Office
  • IT & Server
  • Industrial

IT & Server

  • GXR 1-3 kVA-Table
  • GXR 6-10 kVA
  • GXR-31 10-20 kVA
  • GX 1-3 kVA
  • GX 6-10 kVA
  • GX33 10-30 kVA 3-Phase
  • GXRL Li-Ion 1-3 kVA
  • GXRL-X Li-Ion 1-3 kVA
  • GXR-S 1-3kVA
  • GXR-SI 1-3kVA
  • CXR 1.1-3kVA

Galaxia Rack&Tower

  • GXR-1000
  • GXR-1500
  • GXR-2000
  • GXR-3000
  • GXR-6000
  • GXR-10000


Copyright © 2026 SMAP. All rights reserved.
Privacy Policy | Terms & Conditions | Careers